TSIM 1.1 and TSIM 1.2 use different installers and can be installed
side-by-side on the same machine. To prevent conflicts (for example, with the
.tsim project file association) we recommend
uninstalling TSIM 1.1.x before installing 1.2.x.
01What’s new in 1.2.51
The Getting Started training lessons are now interactive. Open a lesson in the help and click “Start this lesson” to follow it step by step in TSIM, in a new project or the one you have open. A bar in the main window shows your current step and ticks it off as soon as you complete it. “Guide me” highlights where to click, and “Do it for me” does the step for you. Finished lessons are marked with a check in the help’s navigation panel.
The help window opens much faster. TSIM now prepares the full-text search the first time you search, instead of every time the help opens.
New materials now default to the Ring Light curing light. The OmniCure lens setting has been removed, since 6 mm is the only lens available, and the curing light wavelength now offers only 365 nm and 405 nm, the two wavelengths available. Materials and projects that used another wavelength are set to the nearest of the two.
AI assistants connected to TSIM now receive a short modeling guide explaining how to build models in TSIM, such as when to use tubes and splines for print paths and when to use solid objects, and how to keep sketches and their links intact. TSIM also includes a tsim-modeling skill for assistants that support skills; the AI Assistants help page explains how to install it.
Sketch circles keep their exact radius when you reopen a project. Before, the radius was rounded down to a whole millimeter (a 2.8 mm circle reopened as 2 mm), so tubes rebuilt from the sketch came out too small. Projects saved with earlier versions reopen correctly. Pasted sketch circles are fixed too.
New & improvedFixes
02Version history
▶1.2.50Nov 6, 2026AI assistant support, Getting Started training
TSIM can now work with an AI assistant on your computer, such as Claude. Turn on “Allow AI assistants to use TSIM” in Settings (it is off by default) and connect the assistant through the included tsim-mcp program. The assistant can then look at the open project, create, import and edit objects and sketches, run the modeling tools, assign materials and adjust their settings, save the project and send it to the BioAssemblyBot, and you see every change happen in TSIM. Only programs running on this computer under your own user account can connect, and TSIM opens no network port. The new AI Assistants help page explains how to set up Claude Code, Claude Desktop and other assistants that support MCP (Model Context Protocol).
The help now includes a Getting Started training course. Its nine short lessons take you from first launch to sending a print, each ending with a “Try it” exercise, and there is a quick-reference page at the end. Find it under Training in the help’s navigation panel.
Insert Template, Smooth / Refine, Mirror to Defect, Landmark Morph and Deviation now appear in the help’s table of contents, and “Go to Help” on the Insert Template button opens its help page.
Update checks and downloads now use a secure (HTTPS) connection from the very first request. Before, the first request of each check went out over plain HTTP before being redirected.
▶1.2.49Oct 27, 2026New Lattice Fill patterns, density-driven infill
Lattice Fill has many new patterns, covering the infill patterns of the common slicers (PrusaSlicer, Cura, OrcaSlicer and Bambu Studio). The new 2D patterns are Rectilinear, Zig Zag, Tri-Hexagon, Concentric, Cross, Hilbert Curve, Archimedean Chords and Octagram Spiral. The new 3D patterns are Cubic, Quarter Cubic, Octet, 3D Honeycomb, Cross Hatch, Lateral Lattice, Lateral Honeycomb, Gyroid, Schwarz Diamond and Fischer-Koch S. With a 3D pattern, each layer is a slice of one connected 3D structure, so the lattice is close to equally strong in every direction. Where another slicer uses a different name for a pattern, the Lattice Fill help lists it.
Lattice Fill can now be sized by infill density. Switch from pore-driven to density-driven, enter an infill density % as you would in a slicer, and TSIM works out the pore size. The density stays the same when you change the pattern or strut thickness. The panel now shows the approximate density as well as the porosity.
Slice Object and the print simulation now slice objects that have an alternate slicing plane at that plane’s angle. Before, TSIM’s built-in slicer ignored the alternate plane and sliced these objects flat.
The Materials Library settings now have tooltips. Right-click a setting’s label and choose “Go to Help” to open its entry in the help.
Paths made by Combine Tubes, Grid Projector, Project Sketch to Surface, Surface Tubes and Helix print as straight lines again. Before this fix, sending and print simulation bent them into curves, so a combined grid of straight tubes printed with curved lines, for example. Hand-drawn splines stay smooth. Projects saved with older versions open with their generated paths straight, as those versions printed them.
Scaffold Infill paths no longer turn into a jumbled mess after you save and reopen the project.
In the Objects List, an object you add to the selection with Ctrl+click in the 3D view is now highlighted, even when it’s listed above an object that was already selected.
▶1.2.48Sep 24, 2026Slice when sending, Merge Layers improvements
New “Slice objects when sending” setting, on by default. When you send a print, TSIM now slices each solid object with its built-in slicer and sends the resulting print paths to the BioAssemblyBot, so what prints matches what the print simulator shows. Turn it off in Settings to have the BioAssemblyBot slice solid objects itself, as before. Objects set to use the external slicer, objects with an alternate slicing plane, and the container object are unaffected.
Merge Layers now works on more selections. You can select a group, such as the “(sliced)” group that Slice Object creates, to merge everything inside it, or a single object that holds several layers, such as a BioBone scaffold generated with “connect layers” off. Layers made of several loops at the same height are now joined in order instead of being rejected, and the menu shows the number of layers that will be merged.
Merging a BioBone scaffold as a single continuous path turns on its “connect layers” setting and rebuilds it from its pattern sketch, so it stays linked to the sketch. One Undo turns it back into separate layers.
In Generate BioBone Fill, “connect layers” is now on by default, so new scaffolds are built as one continuous tube.
Slice Object no longer appears in right-click menus for objects that can’t be sliced, such as tubes and 3D splines.
Skirt and brim loops from the external slicer no longer appear in sliced objects or the print simulation. They were never sent to the printer.
If the External Slicer Path points at the Slic3r or PrusaSlicer desktop app instead of its console version, TSIM now uses the console version in the same folder rather than opening the slicer window.
Tubes and sliced paths now display sharp turns as rounded corners, the way a printed bead looks, instead of as spikes sticking out past the path.
▶1.2.47Sep 17, 2026Helix surface projection, Slice Object keeps original
The Helix tool can now project onto a surface. Turn on “project onto surface” and pick a mesh, and the spiral drapes over its actual curvature, starting at the apex, with turns equally spaced along the surface. The start and end radii are measured along the surface from the apex, you can define the spiral by revolutions or by pitch, and an “offset from surface” lifts the path off the mesh (for example, half the bead diameter) so a printed bead sits on the surface. Per-point normals follow the mesh so a toolpath can keep the tool perpendicular to the dome.
Slice Object now keeps the original solid in the project and hides it instead of removing it. The generated path objects are placed immediately after it in the project tree; use the visibility control in the Objects List to show the original again.
Projecting a sketch with straight segments (lines, polylines, rectangles) onto a surface now follows the surface along each segment instead of cutting straight through between the projected corners. Corners stay sharp.
▶1.2.46Sep 11, 2026Sketch selection and constraint highlight fixes
Selecting sketch curves now chooses the curve closest to the cursor, with consistent accuracy at different zoom levels.
The Parallel and Angle tools now select the segment under the cursor accurately, even with grid snapping enabled, and use the position where you click.
Hovering over or selecting a sketch constraint now highlights only the segments it applies to, including when both segments belong to the same polyline. Highlights stay aligned as you edit the sketch or undo changes.
▶1.2.45Sep 10, 2026Sketch constraints and BioBone diagram fixes
Sketches gained constraints. New Parallel and Angle tools in the sketch editor let you pick two segments and make them parallel or set the angle between them, typing an exact value in degrees. Constraints are kept while you drag points, edit the table, commit dimensions, or paste, so a segment you have constrained stays put and the rest of the sketch follows.
Constraints are shown as clickable marks on the sketch (“//” for parallel, an arc with its value for angles). Select one and press Delete to remove it, or hide them all with the new “show constraints” checkbox. A status line under the constraint buttons reports how many degrees of freedom remain and flags conflicting or redundant constraints.
An edit that would over-constrain a sketch is rejected without interrupting your work: the constraints that conflict flash so you can see which ones to change. Constraints are removed with their geometry when it is deleted and come back on undo.
The constraint solver is the open-source PlaneGCS library from FreeCAD (LGPL), included with TSIM as a separate component along with its source code. See the third-party notices in the installation folder for details.
The BioBone geometry diagram now draws the number of pores in the design. A single-pore graft is no longer annotated with a spacing it does not have, and the outer-pore marker points at the right channel.
Ctrl+click multi-selection in the sketch editor works again, and dragging a sketch point snaps to grid intersections again.
Visibility and transparency changes in the objects list can now be undone and redone, with changes to a multi-selection restored in one step.
The BioBone panel now includes a to-scale, annotated geometry diagram that connects each measurement to the pattern. It distinguishes pore diameters from width and height when an outer pore is stretched.
New cylinders and spheres default to 32 sides instead of 16 for smoother shapes.
New projects now start with “measure tips on every tool change” turned off.
BioBone designs that cannot fit the requested width and depth now show a clear warning, the smallest achievable graft, and suggestions for adjusting pore count, pore size, line width, or target dimensions. The preview uses the smallest cell instead of a distorted fallback.
Recovered projects now retain their original save location and prompt you to save the recovered work. If recovery fails to load, the recovery copy remains available for another attempt.
Auto-save now resumes correctly for projects containing volume images after being turned off and back on, and saving is more stable while you edit the objects list.
Opening a damaged project now leaves a fresh untitled project, preventing a later Save from overwriting the original file with partially loaded content.
External slicing for print simulation now keeps TSIM responsive and shows a progress dialog with an Abort button. Aborting “Slice Object” also stops the external slicer promptly.
Fixed crashes when creating or opening a project, or closing TSIM, while G-code import, object slicing, or point-cloud surface generation is still running.
Undoing and redoing point-cloud surface generation no longer adds an empty undo step, duplicates the surface, or loses the remaining redo history.
Validate a print against its design — a new “Compare to Model…” command (right-click a point cloud in the project tree or the viewport) measures every scan point against the geometry you designed and recolors the cloud: green where the print is in tolerance, warm colors where there is excess material, cool colors where material is missing, and gray where there is nothing to compare against. The readout gives the percentage in tolerance, the mean and RMS deviation, and the worst excess and missing values, and lists connected out-of-tolerance areas as defect regions you can click to fly the camera to. An optional best-fit alignment separates placement error from print error and reports the offset it found, and the full report can be exported as a CSV for validation records.
Print onto a scanned object — a new “Print With Scan” project mode sends geometry to the printer exactly where you place it against the scan, turning off the printer’s own repositioning, the calibrated well plate, and the stage height offset, so a print can’t slide off the scanned surface. Importing a scan now asks whether to switch the project into the mode, scans are then fetched in the printer’s own coordinate frame, the frame each scan was imported in is saved with the project, and TSIM checks that the connected printer supports the mode before offering it.
Type exact lengths while editing — tube paths and 3D splines now label each segment of the path with its length in millimeters while you edit, and clicking a label lets you type an exact value, the same way sketch dimensions work. A “show segment lengths” checkbox in each panel turns the labels off.
BioBone grafts now come out the size you ask for. Designing to a target size shapes the pore openings to match both the width and the depth instead of holding every cell square — a long, narrow graft used to come back square — and the pore count is now yours to set in both design modes.
A new option runs a BioBone graft’s pores down its depth, turning the pattern a quarter turn for grafts that are deeper than they are wide. It is offered whether you design by target size or by pore size.
Tube walls no longer twist or pinch where merged layers are joined. Scaffolds built with “connect layers” showed shearing exactly where each layer’s stroke starts and ends; only the on-screen tube was affected, never the printed toolpath.
A BioBone pattern’s last leg now runs up to the inner wall and bonds into it, instead of stopping short as a free-standing stub or overshooting into the wall.
Scan points stay visible — the point cloud is now drawn just in front of the surface generated from it rather than sinking into it, and its points no longer shrink to nearly invisible specks after the cloud is selected, dimmed, or hidden and shown again.
The Regenerate Surface dialog’s method descriptions no longer crowd or clip at larger display scales.
▶1.2.42Aug 20, 2026Point cloud cleanup and better scan surfaces
Clean up imported scans - a new “Clean Up Point Cloud” panel (right-click a point cloud in the project tree or the viewport) removes everything that isn’t the object you scanned. Delete every point below a chosen height to drop the stage plane, remove isolated outliers from sensor glitches and reflections, keep only the largest connected cluster to discard debris and fixture edges, keep or remove the points inside a resizable crop box, or downsample a very large cloud to a chosen point spacing. Points about to be removed are highlighted in red first, each operation can be undone on its own, and closing the panel rebuilds the scanned surface from the cleaned cloud.
Better surfaces from scans - importing a scan now also builds a “Scanned Surface” mesh, choosing the reconstruction method to match the scan: a height map for top-down scans, or a full 3D shell when the scan contains walls or undercuts from tilted scanning. Areas the scanner couldn’t reach are left open instead of covered over, so gaps in the scan data stay visible.
New “Regenerate Surface” command on point clouds rebuilds the scanned surface with the method you pick - Automatic, Height map, Full 3D (closed shell), or the Legacy method from earlier TSIM versions - and the change can be undone.
A new optional privacy choice, “Allow AI training on usage data,” lets Advanced Solutions use your shared usage statistics to develop and improve its internal AI models. It is separate from usage sharing, off by default, asked as its own question with both answers weighted equally, and can be changed at any time in Settings; your projects, designs, models, crash reports, and identity are never used for AI training. The license agreement was updated to spell out these terms.
The sketch editing panel now scrolls when its controls don’t all fit in the available height.
▶1.2.41Aug 19, 2026Sketch point deletion and editing stability fixes
Deleting a point from a sketch now removes it from the drawing right away - the deleted point’s marker could previously stay on screen until the view was refreshed.
Fixed crashes when deleting objects, reordering items in the object tree, and undoing or redoing edits. If an edit still can’t be completed, TSIM now stays open and warns you to save your work to a new file instead of closing without notice.
Rewrote the End User License Agreement’s data-collection section to describe usage reporting more plainly and completely - exactly what is collected when reporting is on (and what never is), the 24-month retention limit, and your privacy rights - and the printed and in-app copies of the agreement now carry identical text.
Feedback submissions no longer include your computer name or operating-system user name.
Usage reporting is now more private - reports no longer include your computer name or operating-system user name, and collected data is deleted after 24 months. The Settings description and the End User License Agreement were updated to match.
Turning off usage reporting now takes effect immediately - once disabled, nothing further is transmitted, even during a session that was started while reporting was on.
Size-driven BioBone patterns - a new selector in the Generate BioBone Fill panel lets you design from a target graft size instead of from pore sizes. Enter the target width (X) and depth (Y) and TSIM solves the pattern to hit them, leaving your inner pore size and line width untouched; a readout reports the values it chose and the size actually achieved.
The BioBone preview now draws the graft’s exterior X and Y dimensions directly on the drawing, measured to the outside edge of the printed material, with the Z height in the caption below.
Strengthened usage-reporting privacy - usage reports can only ever contain fixed feature names, so file, folder, and project names can never be recorded, and the End User License Agreement now spells out the opt-in usage reporting terms in detail (what is collected, how it is used, and that it is never shared with third parties).
▶1.2.37Aug 6, 2026Nozzle priming properties, BioBone panel rework, live preview
New material properties for mechanical dispense tools - First Extend adds extra extend at the start of a print to prime the nozzle, and Last Retract adds extra retract at the end of a print to relieve residual pressure and prevent oozing. Both run at the normal extend/retract rate, work in step and volumetric (µL) modes, and are off by default.
The Materials screen now has a draggable divider between the materials table and the properties panel, and the panel scrolls when there isn’t room to show every field.
Reworked the Generate BioBone Fill panel to be easier to understand - enter the inner and outer pore sizes directly in millimeters (no more ratio field), the wall input is now labelled “line width” and the pore count “pores across”, and the readout leads with the overall printed size of the scaffold.
Live BioBone preview - the panel draws a top view of the pattern as you adjust parameters (or pick a saved pattern), using the exact same geometry the Generate button produces.
Improved text contrast in input panel fields so labels and values are easier to read.
Fixed the screen recording (Control+Q) and screenshot (Control+W) shortcuts on macOS - they were being picked up as ⌘Q/⌘W, so they quit the app or closed the window instead of capturing.
▶1.2.36Aug 5, 2026Built-in screen recording and screenshot shortcuts
Built-in screen capture shortcuts - press Ctrl+Q to start and stop a recording of the TSIM window (saved as an .mp4 in your Videos folder) and Ctrl+W to save a screenshot (a .png in your Pictures folder). Capture is silent apart from a small “Recording” indicator in the header, so the footage stays clean. On macOS, use the Control key (not ⌘).
▶1.2.35Jul 31, 2026Sketch-driven objects, BioBone pattern library, point clouds
Sketches now drive the objects built from them - edit or move a sketch and its tube, extrusion, or BioBone scaffold rebuilds to match, keeping its radius, materials, and placement. Right-click an object and choose “Disconnect from Sketch” to freeze it and reuse the sketch elsewhere.
Copy and move sketches from the Sketches panel - a preview follows the cursor, and a copy brings across the geometry, dimensions, reference points, and grid spacing.
Click a dimension label in the viewport to edit it - segment lengths and circle and arc radii are shown while a sketch is open; type an exact value and press Enter.
Set a reference point to anchor a sketch, so changing a dimension moves the connected geometry parametrically instead of stretching a single segment.
Delete individual sketch segments, and merge separate curves into one continuous path with nearby endpoints welded together.
Tube along several sketched curves at once - click them in any order and curves sharing endpoints are chained into a single tube.
Saved BioBone pattern library - save a tuned pattern (including hand edits) under a name and reuse it in any project, with import and export as small .json files.
Edit a generated BioBone pattern sketch by hand and the stacked scaffold regenerates in place, keeping its name, material, and position.
Import point clouds - pull a scan from a connected BioAssemblyBot, or open a .ply file exported from the BAB HMI.
Multi-select in the objects list - hide, lock, dim, or delete every selected object with one click, and copy and paste selections with their group structure intact.
Export a print job to a file from the File menu.
Optional usage data sharing to help improve TSIM, with a privacy setting and a “check for updates” button in Settings.
▶1.2.34Jul 10, 2026Multi-point selection for tubes and splines
Multi-point selection when editing tubes and 3D splines - drag a selection window around several points and move them together with the transform widget or exact numeric entry.
▶1.2.33Jul 6, 2026Numeric distance entry for tube edits
Numeric distance entry when editing tubes - after dragging a tube point, type an exact distance to place it precisely.
▶1.2.32Jul 2, 2026BioBone fill pattern, numeric sketch input, fixes
New BioBone fill pattern, and the BioBone command now finishes automatically after generating.
Numeric input for sketch entities - type exact dimensions while sketching.
Align the sketch grid to any sketch point.
Modernized sketch editor grid rendering, with faster sketch rendering overall.
Toolbar groups containing a single command now start that command directly.
Consistent-diameter tube filters.
Added help to the Settings dialog, including static IP setup instructions.
The 3D view no longer resets when exiting sketch edit mode.
Fixed “Slice Object” on tubes, point clouds, and splines.
Fixed Alt-drag panning while editing a sketch.
Fixed a crash when canceling the Edit Sketch command.
Fixed cropped corners on the unsaved-changes dialog and inconsistent widths on solid modeling input panels.
▶1.2.31Jun 26, 2026DXF import, enhanced tube editing, better help search
DXF import.
Enhanced tube editing, plus a “move stacked object” editing mode for tubes and splines.
Infinite sketch grid, and clicking a sketch in select mode now enters edit mode.
Improved help search that works like Word and other familiar apps.
Renamed the “print continuously” checkbox for clarity.
▶1.2.30Jun 26, 2026Material search, sketch line editing, smarter slicing
Search in the materials library.
Delete and separate lines in sketches; dimensions are displayed while sketching.
Improved slicing around open holes and internal voids in models.
Tooltips on all panels, with right-click access to help.
Better error handling when simulating with an external slicer.
Crash reporting re-enabled.
Fixed right-click “edit material” while searching materials.